Miscellaneous Events
The following table provides events related to hardware and software components like mezzanine cards, sensors, firmware etc. and compatibility issues.
| Description | Severity | Cause |
|---|---|---|
| System Board Video Riser: Module sensor for System Board, device removed was asserted | Critical | This event is generated when the required module is removed. |
| Mezz B<slot number> Status: Add-in Card sensor for Mezz B<slot number>, install error was asserted | Critical | This event is generated when an incorrect Mezzanine card is installed for I/O fabric. |
| Mezz C<slot number> Status: Add-in Card sensor for Mezz C<slot number>, install error was asserted | Critical | This event is generated when an incorrect Mezzanine card is installed for I/O fabric. |
| Hdwar version err: Version Change sensor, hardware incompatibility was asserted | Critical | This event is generated when an incompatible hardware is detected. |
| Hdwar version err: Version Change sensor, hardware incompatibility (BMC firmware) was asserted | Critical | This event is generated when a hardware is incompatible with the firmware. |
| Hdwar version err: Version Change sensor, hardware incompatibility (BMC firmware and CPU mismatch) was asserted | Critical | This event is generated when the CPU and firmware are not compatible. |
| Link Tuning: Version Change sensor, successful software or F/W change was deasserted | Warning | This event is generated when the link tuning setting for proper NIC operation fails to update. |
| Link Tuning: Version Change sensor, successful hardware change <device slot number> was deasserted | Warning | This event is generated when the link tuning setting for proper NIC operation fails to update. |
| LinkT/FlexAddr: Link Tuning sensor, failed to program virtual MAC address (Bus # Device # Function #) was asserted | Critical | This event is generated when Flex address can be programmed for this device. |
| LinkT/FlexAddr: Link Tuning sensor, device option ROM failed to support link tuning or flex address (Mezz <location>) was asserted | Critical | This event is generated when ROM does not support Flex address or link tuning. |
| LinkT/FlexAddr: Link Tuning sensor, failed to get link tuning or flex address data from BMC/iDRAC was asserted | Critical | This event is generated when link tuning or Flex address information is not obtained from BMC/iDRAC. |
| The <name> is removed. | Critical | This event is generated when the device was removed. |
| The <name> is inserted. | Information | This event is generated when the device was inserted or installed. |
| A fabric mismatch detected between IOM and mezzanine card <number>. | Critical | This event is generated when an incorrect Mezzanine card is installed for I/O fabric. |
| Hardware incompatibility detected with mezzanine card <number>. | Critical | This event is generated when an incorrect Mezzanine card is installed in the system. |
| The QuickPath Interconnect (QPI) width degraded. | Warning | This event is generated when the bus is not operating at maximum speed or width. |
| The QuickPath Interconnect (QPI) width regained. | Information | This event is generated when the bus is operating at maximum speed or width. |
| BIOS detected an error configuring the Intel Trusted Execution Technology (TXT). | Critical | This event is generated when TXT initialization failed. |
| Processor detected an error while performing an Intel Trusted Execution Technology (TXT) operation. | Critical | This event is generated when TXT CPU microcode boot failed. |
| BIOS Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) error during POST. | Critical | This event is generated when TXT Post failed. |
| SINIT Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) error at boot. | Critical | This event is generated when the Authenticated Code Module detected a TXT initialization failure. |
| Intel Trusted Execution Technology (TXT) is operating correctly. | Information | This event is generated when the TXT returned from a previous failure. |
| Failure detected on Removable Flash Media <name>. | Critical | This event is generated when the SD card module is installed but improperly configured or failed to initialize. |
| Removable Flash Media <name> is write protected. | Warning | This event is generated when the module is write-protected. Changes may not be written to the media. |
| Internal Dual SD Module is redundant. | Information | This event is generated when both SD cards are functioning properly. |
| Internal Dual SD Module redundancy is lost. | Critical | This event is generated when either one of the SD cards or both the SD cards are not functioning properly. |